The ODCER transformer is a modern electrical device specially designed to convert the voltage of the contact network into the voltage required to power the traction motors of AC electric trains. Its functional capabilities allow it to work effectively in conditions of increased mechanical loads, vibrations and temperature fluctuations. Thanks to the use of advanced technologies, the transformer provides high reliability and energy efficiency when operating in difficult conditions of railway transport.

Design features

The ODCER transformer has a robust design, which is specially adapted for open installation under the body of an electric train. This provides maximum resistance to mechanical influences, such as shaking, shocks and vibrations that occur during the movement of the railway train. The transformer housing is made of high-quality materials, which guarantee protection against moisture, dust and aggressive external factors.

Its design includes:

  • Power winding with optimized insulation for increased electrical strength.
  • An effective cooling system that ensures stable thermal conditions.
  • Anti-vibration mounts to reduce the impact of dynamic loads.
  • Protective coating for operation in conditions of increased humidity and dust.

Technical characteristics of ODCER transformers

Transformer parameters

Parameter Value
Power supply frequency, Hz 50
Scheme and group of winding connections 1\1-1-1-0-0-6
Nominal power of the network winding (MO), kV·A 965
Nominal voltage of the mains winding (MO), kV 25
Rated voltage of traction windings (TO) at the inputs, V 2208 (1-8)
Rated current of traction windings (TO), A 350
Nominal power of the winding of own needs (OVP), kV·A 92
Nominal voltage of the self-consumption winding (SW) at the inputs, V 220 (x1-o1), 276 (x2-o1)
Nominal power of the heating winding (OP), kV·A 100
Nominal voltage of the heating winding (HW) at the inputs, V 628 (o1-a1)
Rated current of the heating winding (OP), A 159
Total transformer losses, kWt 22
Transformer efficiency, %, not less 97,5
Weight of the transformer in ready condition, kg 3600

Reactor parameters

Rated rectified current, A 400
Variable component of current, A 85
Individuality at a magnetizing current of 250 A, mH 22
Individuality at bias current 530 A, mH 17
Copper losses, kWt 9,5

Залізничний трансформатор серії ОДЦЕР

Download PDF

Advantages of using ODCER transformers

  • Reliability in difficult conditions: The ODCER transformer is able to operate in difficult climatic and mechanical conditions thanks to its robust design and efficient cooling system.
  • High energy efficiency: Minimal energy losses ensure economical operation.
  • Vibration and shock resistance: Design solutions reduce the risk of damage during intensive operation.
  • Durability: The use of high-quality materials guarantees a long service life without loss of operational characteristics.

Areas of application

The ODCER transformer is widely used in the following industries:

  • Railway transport: For powering traction motors of AC electric trains.
  • Subways: For electric trains and special rolling stock.
  • Industrial transport: At enterprises with their own railway infrastructure.
  • Electric power industry: For specialized voltage conversion systems.

Compliance with standards

The ODCER transformer complies with all current international and national safety and quality standards. In particular, it is certified in accordance with IEC standards, which regulate the requirements for power transformers, ISO, which confirms an effective production quality management system, and also meets the requirements of GOST for the climatic performance of the equipment.

For more detailed information and advice on the selection of ODCER transformers, please contact the official representative of Ukrelectroaparat LLC.

ODTSER
Download

Тechnical catalog

Transformers
Download

Questionary list

Loading